Input Parameters
Here is a list of available input arguments in the TOML file.
Parameters
- nD: dimension of the system
- 1, 2, 3
- Scheme: numerical schemes to be used
"Rusanov"
"HLLE"
- Order: order of accuracy
- 1
- 2
- CFL: stability control parameter, (0,1)
- limiter: slope limiter for the 2nd order schemes
"MM"
: minmod"MC"
: monotonized central difference
- TimeAccurate: logical for running in time accurate mode
true
false
- UseConservative: logical for using energy conservation equation
true
false
- IC: initial conditions
"density wave"
"square wave"
"contact discontinuity"
"Riemann"
- RiemannProblemType: [1,12]
- nStep: total number of steps
- tEnd: end time in time accurate mode
Grid
- TypeGrid: coordinate system
"Cartesian"
- xyzMinMax: range of the coordinates
- [[0.0, 1.0]]
- nI: number of cells in the first dimension
- nJ: number of cells in the second dimension
- nK: number of cells in the third dimension
- BCtype: boundary conditions
["float", "float"]
["periodic", "periodic"]
Plots
- DoPlot: logicals for plotting
true
false
- PlotVar: variable name to be plotted
"rho"
"ux"
"p"
- PlotInterval: plotting frequency in steps
- PlotType: type of plots
- ["x", "1D"]